- Home
- Search Results
- Page 1 of 1
Search for: All records
-
Total Resources2
- Resource Type
-
0000000002000000
- More
- Availability
-
11
- Author / Contributor
- Filter by Author / Creator
-
-
Glover, T Grant (2)
-
Hastings, Jon (2)
-
Lassitter, Thomas (2)
-
Chheda, Saumil (1)
-
Farha, Omar K (1)
-
Formalik, Filip (1)
-
Gagliardi, Laura (1)
-
Hupp, Joseph T (1)
-
Liu, Jiayang (1)
-
Siepmann, J Ilja (1)
-
Snurr, Randall Q (1)
-
Wang, Zhiwei (1)
-
Xie, Haomiao (1)
-
Yaghi, Omar M (1)
-
Zheng, Zhiling (1)
-
#Tyler Phillips, Kenneth E. (0)
-
#Willis, Ciara (0)
-
& Abreu-Ramos, E. D. (0)
-
& Abramson, C. I. (0)
-
& Abreu-Ramos, E. D. (0)
-
- Filter by Editor
-
-
& Spizer, S. M. (0)
-
& . Spizer, S. (0)
-
& Ahn, J. (0)
-
& Bateiha, S. (0)
-
& Bosch, N. (0)
-
& Brennan K. (0)
-
& Brennan, K. (0)
-
& Chen, B. (0)
-
& Chen, Bodong (0)
-
& Drown, S. (0)
-
& Ferretti, F. (0)
-
& Higgins, A. (0)
-
& J. Peters (0)
-
& Kali, Y. (0)
-
& Ruiz-Arias, P.M. (0)
-
& S. Spitzer (0)
-
& Sahin. I. (0)
-
& Spitzer, S. (0)
-
& Spitzer, S.M. (0)
-
(submitted - in Review for IEEE ICASSP-2024) (0)
-
-
Have feedback or suggestions for a way to improve these results?
!
Note: When clicking on a Digital Object Identifier (DOI) number, you will be taken to an external site maintained by the publisher.
Some full text articles may not yet be available without a charge during the embargo (administrative interval).
What is a DOI Number?
Some links on this page may take you to non-federal websites. Their policies may differ from this site.
-
Metal-organic frameworks (MOFs) have been examined extensively for CO2 capture, and the influence of water co-adsorption on these processes is particularly relevant, as CO2 capture generally occurs in humid gas streams. To investi-gate CO2/H2O co-adsorption, binary adsorption isotherms of CO2 and H2O were measured on MOF-808-TFA (TFA = trifluoro-acetic acid). When water was pre-adsorbed on MOF-808-TFA, and a subsequent CO2 adsorption isotherm was measured, the CO2 adsorption was slightly reduced, as expected. However, when CO2 was adsorbed first and then an H2O adsorption iso-therm was measured, no significant H2O adsorption capacity was observed. The near complete loss of water adsorption ca-pacity was observed even when only a trace amount of CO2 was pre-adsorbed. The results show that unexpected, non-state function adsorption equilibria can result from dynamic MOF behaviors and defect sites, which may lead to counterintuitive adsorption data compared to traditional materials.more » « lessFree, publicly-accessible full text available October 22, 2026
-
Hastings, Jon; Lassitter, Thomas; Zheng, Zhiling; Chheda, Saumil; Siepmann, J Ilja; Gagliardi, Laura; Yaghi, Omar M; Glover, T Grant (, The Journal of Physical Chemistry C)
An official website of the United States government
